A highly selective and sensitive pyridylazo-2-naphthol-poly (acrylic acid) functionalized electrospun nanofiber fluorescence “turn-off” chemosensory system for Ni 2+
- Authors: Adewuyi, Sheriff , Ondigo, Dezzline A , Zugle, Ruphino , Tshentu, Zenixole R , Nyokong, Tebello , Torto, Nelson
- Date: 2012
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/246012 , vital:51428 , xlink:href="https://doi.org/10.1039/C2AY25182E"
- Description: A fluorescent nanofiber probe for the determination of Ni2+ was developed via the electrospinning of a covalently functionalized pyridylazo-2-naphthol-poly(acrylic acid) polymer. Fluorescent nanofibers with diameters in the range 230–800 nm were produced with uniformly dispersed fluorophores. The excitation and emission fluorescence were at wavelengths 479 and 557 nm respectively, thereby exhibiting a good Stokes' shift. This Ni2+ probe that employs fluorescence quenching in a solid receptor–fluorophore system exhibited a good correlation between the fluorescence intensity and nickel concentration up to 1.0 μg mL−1 based on the Stern–Volmer mechanism. The probe achieved a detection limit (3δ/S) of 0.07 ng mL−1 and a precision, calculated as a relative standard deviation (RSD) of more than 4% (n = 8). The concentration of Ni2+ in a certified reference material (SEP-3) was found to be 0.8986 μg mL−1, which is significantly comparable with the certified value of 0.8980 μg mL−1. The accuracy of the determinations, expressed as a relative error between the certified and the observed values of certified reference groundwater was ≤0.1%. The versatility of the nanofiber probe was demonstrated by affording simple, rapid and selective detection of Ni2+ in the presence of other competing metal ions by direct analysis, without employing any further sample handling steps.
- Full Text:
- Date Issued: 2012
Pre-concentration of toxic metals using electrospun amino-functionalized nylon-6 nanofibre sorbent
- Authors: Darko, Godfrey , Sobola, Abdullahi O , Adewuyi, Sheriff , Okonkwo, J O , Torto, Nelson
- Date: 2012
- Language: English
- Type: Article
- Identifier: vital:6571 , http://hdl.handle.net/10962/d1004134
- Description: This paper presents a new approach for pre-concentrating toxic metals (As, Cd, Ni and Pb) in aqueous environments using an amino-functionalized electrospun nanofibre sorbent. The sorbent, composed of nanofibres of average diameter 80 ± 10 nm and specific surface area of 58m2 g–1, exhibited fast adsorption kinetics (<20 min) for As, Cd, Ni and Pb. The optimalpHfor the uptake of As, Cd, Ni and Pb were 5.5, 6.0, 6.5 and 11, respectively. The adsorption process best fitted the Freundlich isothermand followed the first-order kinetics. The highest pre-concentration achieved using the sorbent was 41.99 (Ni in treated wastewater). The capacity of the sorbent to pre-concentrate the toxic metals was compared with those of aqua regia and HNO3+H2O2 digestions. The pre-concentration factors achieved for Cd in river water samples can be ranked as aqua regia digestion (0.73) > adsorption (0.34)>HNO3+H2O2 (0.23) digestion.Asimilar trend was observed for Ni in river water as well as Ni andCdin tap water samples. Pb ions in the river water samples were pre-concentrated slightly better using the two digestion methods pre-concentration factors ~22) compared to adsorption method (pre-concentration factor ~21). The use of the electrospun amino-functionalized nanofibre sorbent presentsanefficientand cost-effective alternative for pre-concentration of toxic metals inaqueousenvironments.
- Full Text:
- Date Issued: 2012